久久网黄色_国产中文字幕在线播放_亚洲熟妇丰满xxxxx国语_久久艹精品_亚洲精品久久久无码白峰美_品久久久久久久久久96高清

Home Product General?Instruments Ultrasonic equipment Non-contact shaped DNA interrupter
Non-contact shaped DNA interrupter

Model:XM-26A

Brand:Xiaomei Ultrasound

Specifications :Set

Introduction:In the traditional ultrasonic breaker with probe, the probe is in direct contact with the sample, only one sample can be processed at a time, and the experiment period is long;

main application:

1. Working principle:

In the traditional ultrasonic breaker with probe, the probe is in direct contact with the sample, only one sample can be processed at a time, and the experiment period is long; for multiple samples, the same probe needs to be used repeatedly, which may easily cause sample cross-contamination. Because the depth of the probe inserted into the sample is different each time, the energy distribution of each ultrasound is different, which affects the repeatability and accuracy of the experimental results. In addition, since a closed system cannot be used, the aerosol or foam generated during the ultrasound process will diffuse into the environment, causing potential biological hazards.

The non-contact ultrasonic breaker can process up to 16 samples at the same time at a time, and the experiment efficiency is high; there is no need to operate the probe frequently, and each sample is in a separate fully enclosed test tube to avoid cross-contamination; the 4℃ water bath ultrasonic wave is used, and the energy distribution is even. The effect of ultrasound is complete; the ultrasound parameter settings are flexible, the experimental steps are standardized, the experimental repeatability is good, and the results are highly reliable.

2. Components:

Ultrasonic power/time adjustment and 7-inch LCD touch screen host, ultrasonic water tank and anti-noise upper cover, adapter rotating upper cover, centrifuge tube fastening lower cover, 0.5-10ml multiple adapters and portable cooling cycle machine.

3. Main functions:

It is mainly used for bacterial cell disruption, protein extraction, DNA fragmentation of second-generation sequencing samples, immunoprecipitation experiments, mold spore fragmentation, emulsification, homogenization, speeding up dissolution, and catalyzing reactions.

Technical parameters:

Technical parameters

Parameter range

model

XM-26A single channel

Ultrasound frequency

20-400KHz mixing ultrasonic function, frequency adaptive

Ultrasound nominal power

adjustable power: 0-100%,Step 10%, can also be refined to 1% step

Ultrasound nominal power

0.1s-9999min, pulse gap time is adjustable: 0.1s-99.9s

Ultrasonic tank volume

15*14*250px

Imported original multi-frequency ultrasonic transducer

3 groups

Ultrasound sample volume

2mL or more or 5uL or less

Number of samples processed

30*0.1mL,20*0.65mL,11*2mL
And 5 5-15mL centrifuge tubes

Adapter material

316 stainless steel

Noise level

<55dB

cooling system

Portable thermostatic bath host (compressor refrigeration)

Temperature control range

2-40°C

Compressor power

600W

Temperature reading accuracy

at 0.1°℃

Cooling capacity

150W

The main parameters:

Technical parameters

Parameter range

Manipulation method:

Ultrasonic sample volume:

With different adapters, the ultrasonic sample volume can reach more than 2ml or less than 5ul.

Applicable sample types:

Applicable sample types include 0.1ml, 0.65ml, 1.5ml and 15ml centrifuge tubes, without using special materials (such as glass) consumables, saving experiment costs.

Sample crushing work:

The sample needs to be crushed in a closed container, no infectious flying mist is generated, and no additional ultrasonic probe (probe) needs to be inserted.

Constant speed rotation:

The sample needs to be able to automatically rotate at a constant speed during ultrasonication to ensure that the sample crushing effect is consistent.

Allowable number of single operations:

Up to 34 samples can be processed at one time (with a 0.1 or 0.65ml adapter).

Sample fragmentation method:

Magnetic resonance ultrasonic technology is used to crush samples, nucleic acid samples in the range of 1KB to 200bp or less.

Ultrasonic control:

Working mode:

7-inch touch screen touch operation, simple and convenient operation; real-time display of working parameters on the screen, cumulative display of running status; micro-processing controller can store more than 20 groups of working programs, 99 hours of process control timer control total time: 1 second to 99 hours, 99 minutes and 99 seconds, to meet different experimental needs.

The digital display of a single water tank has the function of overheating and power failure protection. The ultrasonic power is infinitely adjustable, and the step is one percent. The power acting on the sample is 50W, 100W, 150W, 200W, 250W, 280W, 320W, 400W, 450W, 480W and 500W are suitable for experiments with different samples, and the ultrasonic power has a wide adjustable range, which meets the requirements of more precise experiments.

Ultrasound can work continuously for 60 minutes, and it can also work at intervals. Interval time: 1-999 seconds.

With overheating protection function.

Transducer size: 13*325px round, energy-concentrating type to generate ultrasonic energy.

The volume of the ultrasonic tank is ≥1000mL.

An external MINI chiller can be used to cool the ultrasonic tank to ensure the required low temperature environment for the sample.

The sample needs to be broken in a closed container, no infectious flying mist is generated, and no additional ultrasonic probe needs to be inserted.

The sample is automatically rotated at a constant speed during ultrasound to ensure consistent sample crushing effects.

Allowable number of single operations: Up to 34 samples can be processed at one time (with a 0.1-0.5ml adapter).

The instrument contains four kinds of adapters: 0.5ml, 1.5ml, 2ml and 5ml: with a knob-type centrifuge tube sample leak-proof safety lock, at least 6 1.5ml centrifuge tubes, 34 0.1ml centrifuge tubes, and 2ml and 5ml centrifuges can be used at the same time Tube, the single sample volume can be between 100μl ~ 300μl.


Standard configuration:

1. Ultrasound host

2. Ultrasonic sink and anti-noise box

3. The adapter rotates the upper cover

4. The centrifuge tube is fastened to the lower cover, 0.5-10ml various adapter centrifuge tubes

5. Portable cooling cycle machine


Related Products
Inquiry message
*Name:

*Company/City:
*Phone:
*Contact:
*City:
*Code:
主站蜘蛛池模板: 草1024榴社区成人影院 | 日韩视频福利 | 被强到爽的邻居人妻 | porno—365hd | 筱崎爱全部a级a做爰视频 | BBW厕所白嫩BBWXXXX | 国产又粗又猛又爽又黄a片 俄罗斯女人╳69 | 欧美人妻少妇精品久久黑人 | 91欧洲在线视精品在亚洲 | 久久综合色播五月 | 国产精品人人妻人色五月 | 伊人久久中文字幕 | 麻豆视频国产在线观看 | 老女人碰碰在线碰碰视频 | 久久免费看视频 | 亚洲精品一二三 | 日韩人妻无码精品久久免费一 | 国产香蕉97碰碰视频VA碰碰看 | 好男人好资源在线观看免费的 | 国产交换配乱淫视频免费 | 久久一本久综合久久爱 | 色噜噜日韩精品一区二区三区视频 | 国内精品51视频在线观看 | 我要看一级黄 | 大桥未久在线视频 | 一区二区三视频 | 九七超碰在线 | 狼人av官网| 国产精品视频一区二区三区 | 国产免费一级淫片a级中文 日韩三级视频在线观看 | 日本高清视频网站WWW | 国产美女www爽爽爽 日韩精品一区二区亚洲 | 大地资源网 中文在线观看 涩涩网站在线 | 久久久亚洲精华液精华液精华液 | 一本到无码av专区无码不卡 | 国产一级18片视频 | 欧美v在线 | 国产午夜精品久久久久免费视 | 国产激情无码一区二区 | 男人的天堂无码动漫AV | 爽妇av |